Centaur Charger |
Victron Centaur Charger
Quality without compromise
Aluminium epoxy powder coated cases with drip shield and stainless
steel fixings withstand the rigors of an adverse environment: heat, humidity
and salt air. Circuit boards are protected with an acrylic coating for
maximum corrosion resistance. Temperature sensors ensure that power components
will always operate within specified limits, if needed by automatic reduction
of output current under extreme environmental conditions.
Universal 90 to 265 Volt input voltage range
All models will operate without any adjustment needed over a 90 to
265 Volt input voltage range, whether 50 Hz or 60 Hz.
Three outputs that each can supply the full output current
Three isolated outputs to simultaneously charge 3 battery banks. Each
output is capable to supply the full rated current.
Three stage charging, with temperature compensation
The Centaur charges at bulk rate until the output has reduced to 70
% of the rated Amps, at which a 4 hour timer begins. After the timed period
the charger switches to float rate. An internal temperature sensor is used
to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per
cell.
A dip switch is available to select the optimum charge/float voltages
for Flooded Lead-acid, Gel or AGM batteries.
Intelligent, microprocessor controlled version
For the ultimate in battery charging we recommend our Microprocessor
Controlled Phoenix range.
Important features of the Phoenix Charger range are:
- adaptive 4-stage charging with variable absorption time, BatterySafe
mode and Storage mode
- VENet: RS-485 interface for remote control, monitoring and computer
assisted setting of all
parameters
- battery temperature sensor
- battery voltage sensor
Specifications
|
Centaur Charger
|
12/20
|
12/30
24/16
|
12/40
|
12/60
24/30
|
12/80
24/40
|
12/100
24/60
|
12/200
24/100
|
|
Charge voltage (V DC)
|
14,3
|
14,3 / 28,5
|
14,3
|
14,3 / 28,5
|
14,3 / 28,5
|
14,3 / 28,5
|
14,3 / 28,5
|
|
Charge voltage float (V DC)
|
13,5
|
13,5 / 27,0
|
13,5
|
13,5 / 27,0
|
13,5 / 27,0
|
13,5 / 27,0
|
13,5 / 27,0
|
|
Output banks
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
|
Charge current (A)
|
20
|
30 / 16
|
40
|
60 / 30
|
80 / 40
|
100 / 60
|
200 / 100
|
|
Total output ammeter
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Charge characteristic
|
IUoU*
|
IUoU*
|
IUoU*
|
IUoU*
|
IUoU*
|
IUoU*
|
IUoU*
|
|
Recommended battery capacity (Ah)
|
80 - 200
|
120-300
45-150
|
160-400
|
240-600
120-300
|
320-800
160-400
|
400-1000
240-600
|
800-2000
400-1000
|
|
Forced cooling
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Operating temp. range
|
-20 to 60°C
|
-20 to 60°C
|
-20 to 60°C
|
-20 to 60°C
|
-20 to 60°C
|
-20 to 60°C
|
-20 to 60°C
|
|
Humidity
|
max 95%
|
max 95%
|
max 95%
|
max 95%
|
max 95%
|
max 95%
|
max 95%
|
|
Enclosure
|
|
|
|
|
|
|
|
|
Battery-connection
|
M6 Studs
|
M6 Studs
|
M8 Studs
|
M8 Studs
|
M8 Studs
|
M8 Studs
|
M8 Studs
|
|
Protection category
|
IP 21
|
IP 21
|
IP 21
|
IP 21
|
IP 21
|
IP 21
|
IP 21
|
|
Weight kg (Ibs)
|
3,8
|
3,8
|
5,0
|
5,0
|
12,0
|
12,0
|
16,0
|
|
Dimensions in mm
|
355x215x110
|
355x215x110
|
426x239x135
|
426x239x135
|
505x255x130
|
505x255x130
|
505x255x230
|
* Three stage charging
more specifications:
- Common characteristics: Input voltage: 90-265V, input frequency:
45-65 Hz, Power factor: 1
- Temperature sensor: Internal,-2mV / °C (-1mV / °F) per cell
- Protection: Output short circuit, over temperature
- Material & Color: aluminium (blue RAL 5012)
- AC-connection: screw-clamp 4 mm² (AWG 6)
Standards:
Safety: EN 60335-1, EN 60335-2-29, UL 1236
Emission: EN 55014-1, EN 61000-3-2
Immunity: EN 55014-2, EN 61000-3-3
Installation
1.Fasten the separate mounting plate (A)
to the wall where you want to
place the battery charger and simply
hook up the Centaur.
2. Secure the bottom of the backside (B)
to the wall.
|
|
More information in the multilanguage manual
(500 kB pdf)
|